Specifications
-| Model | 4103D12VCB46M |
|---|---|
| Certification | ASME. UL, CSA |
| Overall Length | 40" |
| Overall Width | 30 |
| Overall Height | 75 |
| Overall Weight | 1,000 Lbs |
| HP | 10 |
| Voltage | 460V |
| Phase | Three Phase |
| Power Type | Electric |
| Amp Draw | 14 |
| Recommended Breaker | Consult Certified Electrician |
| CFM | 35 |
| CFM Rated @ | 175 PSI |
| Max PSI | 175 PSI |
| Tank Size | 120 |
| Tank Orientation | Vertical |
| Tank Outlet | 1" |
| Pump Type | Two-Stage |
| Pump Drive | Belt Drive |
| Pump Material | Cast Iron w/ Aluminum Head |
| Pump Low Oil Shut-off | Yes |
| Oil Type | Oil Lubricated |
| Oil System | Splash Lubricated |
| Oil Sight Glass | Yes |
| Air Dryer | No |
| After Cooler | Yes |
| Magnetic Starter | Yes |
| Electronic Drain Valve | No |
| Consumer Warranty | 1 Year |
| Commercial Warranty | 1 Year |
Warranty
-Description
-Quincy 4103D12VCB46M QT MAX - 10 HP, 120 Gallon Vertical, Two-Stage, 460V 3-Phase
A compressor rated to run continuously spends most of its life with nobody watching it. What matters then is not how well it starts but how reliably it stops. This QT MAX carries two independent shutdowns: a magnetic starter with thermal overload protection that drops the motor out before it can cook its own windings, and a low oil cut-off switch that halts the machine before a pump can run itself dry. They guard different failures, and either one can save the machine on its own.
Around them, a 10 HP motor on 460 Volt 3-phase supply, a splash-lubricated cast iron two-stage pump delivering 35 CFM at 175 PSI into a 120 gallon vertical ASME tank, rated for 100% duty cycle.
Two things to check before you order
The part number. The product title, the description heading and the specification block all read 4103D12VCB46M. The web address of this page, and one sentence in the current description, read 2103D12VCB46M. Both are printed here. Give us the code on your quote or purchase order and we will confirm the build with the manufacturer before it is made.
The automatic tank drain. Published details differ: the feature list and the description say an automatic electronic tank drain is fitted, while the specification field for the electronic drain valve says it is not. If an automatic drain is part of why you are buying this machine, ask us to confirm it in writing first.
The two shutdowns, and why both are needed
A magnetic starter is not a switch. It is a contactor with an overload relay that watches the current the motor is drawing, and drops it out when that current says the motor is in trouble - a stalled pump, a failed phase, a seized bearing. Without one, a struggling motor keeps drawing until something gives, and on a 460 Volt 3-phase machine the something is usually the windings. Quincy fits and wires the starter at the factory, so your installation is a supply run rather than a control panel build.
The low oil cut-off protects a different failure entirely. A motor overload relay knows nothing about oil level; it will happily keep a healthy motor turning a pump that has run its sump low. The cut-off switch monitors that directly and stops the machine before the bearings and rings are damaged. On a compressor that runs unattended for hours at a time, this is the shutdown that actually earns its keep - a slow leak or a missed service becomes a machine that stopped, not a machine that seized.
An oil sight glass is fitted alongside them, and it is worth using. Both cut-offs are last lines of defence; a five-second look at the glass before each shift is the first.
Why 460 Volt, and what the electrician needs
This is the build for a plant already running at 460 Volt. Higher supply voltage draws less current for the same shaft power, which generally means lighter conductors and a smaller feeder than the lower-voltage versions of the same machine.
How much smaller depends on your run and your code, which is exactly why Quincy publishes no breaker figure and instead records the requirement as consult a certified electrician. Settle the feeder, the disconnect and the protection before you order: this build is wired for one voltage and cannot be converted to another when it arrives.
Running slow on purpose
The QT MAX pump is geared to turn at a deliberately low speed for its output. Slower means cooler, cooler means the oil film survives, and a machine that runs cool is a machine that can hold a 100% duty rating honestly rather than on paper. It is also considerably less unpleasant to work beside than a small high-speed compressor labouring to keep up with the same demand. The cooling package supports the same aim - a finned intercooler between the stages, and an air-cooled aftercooler before the tank.
Will it fit
Vertical tank: about 40 inches by 30 inches of floor, roughly 75 inches tall, 1,000 lbs. Check ceiling height and the clearance of every door, shutter and overhead track on the route in. Level, solid concrete, with space around the machine so the coolers get moving air. Confirming the pad, the clearances and the access route before delivery is the customer responsibility.
Specifications
| Model | 4103D12VCB46M (a second code appears in our data - see above) |
|---|---|
| Motor | 10 HP, 460 Volt, 3-phase |
| Delivered air | 35 CFM at 175 PSI |
| Duty cycle | 100% |
| Pump | Two-stage, cast iron with aluminum head, enclosed belt drive, splash lubricated |
| Motor protection | Magnetic starter with thermal overload, factory wired |
| Pump protection | Low oil cut-off switch, oil sight glass |
| Cooling | Finned interstage intercooler and air-cooled aftercooler |
| Tank | 120 gallon, vertical, ASME |
| Tank outlet | 1 inch |
| Dimensions | 40 inches by 30 inches, 75 inches tall |
| Weight | 1,000 lbs |
| Automatic tank drain | Published details differ - confirm before ordering |
| Warranty | 1-year factory, extending to a 3-year term on the manufacturer conditions |
Perfect For
- Plants already on 460 Volt where matching the existing service avoids a transformer.
- Unattended or lights-out running, where the protective shutdowns are what stands between a fault and a replacement machine.
- Continuous-demand shops - blasting, finishing, production assembly - that need 35 CFM without a rest period.
- Maintenance teams who would rather find a stopped compressor than a seized one.
Wrong for a home workshop. No house has a 460 Volt 3-phase supply, and this is 1,000 lbs of industrial machine.
What Is In The Box
Delivered factory assembled: two-stage pump, motor, enclosed belt drive and guard mounted on the 120 gallon vertical tank, with magnetic starter, low oil cut-off switch, oil sight glass, intercooler and aftercooler in place. Warranty documentation ships with it.
You provide the electrical supply, disconnect and protection, pipework beyond the 1 inch tank outlet, any downstream filtration or drying, isolation pads and first-service consumables. No air dryer is fitted to this model.
Certification, stated honestly
The manufacturer certification record for this unit lists an ASME tank together with UL and CSA marks. Those describe the machine as it was built and tested.
They describe nothing about your site. No mark on a compressor certifies your feeder, your disconnect, your overcurrent protection or your ventilation against the code that applies where you are - that is your electrician work, confirmed by an inspector where a permit is required. If an insurer or an authority having jurisdiction needs the documentation, ask us before you order and we will obtain it from the manufacturer rather than leave you to discover a gap at commissioning.
Shipping and delivery
Freight only, to the lower 48 states. The cost is quoted live at checkout from the ZIP code you enter, so it prices your address instead of an average. Residential delivery carries a residential fee; a commercial address with a dock or forklift is cheaper, and terminal pickup cheaper again.
You must be able to unload it. The driver goes as far as the kerb. Getting 1,000 lbs off the trailer needs a forklift, a loading dock, or a terminal collection you have equipped yourself for.
Inspect before you sign. Walk the crate, look at the tank, the coolers, the pump and the motor, and write any damage onto the bill of lading before the driver leaves. Once a clean receipt is signed, a freight claim becomes an uphill argument.
Warranty
This unit carries a 1-year factory warranty, and Quincy makes it eligible for an extended 3-year term when the registration and maintenance conditions the manufacturer sets are met. Those conditions are the manufacturer to define and they change, so confirm the current requirements with us in writing before you rely on them.
The standing warning applies here as to any compressor: do not take the pump, the motor or the starter apart before the claim is raised. A dismantled unit is very difficult to warrant however plain the fault seemed. Call us first, keep every component, and photograph the condition you found.
Frequently Asked Questions
Everything you need to know about our products and services
After placing your order, you'll receive a confirmation email within minutes. Our team will process your order within 1–2 business days. For large items like vehicle lifts, a freight carrier will contact you to schedule delivery. Smaller items ship via UPS or FedEx.
We offer a 30-day return policy for most items in original, unused condition. Vehicle lifts and heavy equipment may have restocking fees. Freight items must be inspected at delivery and any damage noted on the bill of lading. Contact us within 48 hours of delivery for damage claims.
Absolutely! We offer special pricing for shops, contractors, and bulk orders. Contact our sales team at 866-774-7743 or email sales@mechanicsuperstore.com for a custom quote. Volume discounts start at 3+ units.
Tracking information is sent once your order ships. If you haven't received it within 2 business days, check your spam folder. You can also track your order by logging into your account or contacting our support team at support@mechanicsuperstore.com.
Standard orders ship within 1–3 business days. Freight items (lifts, compressors) typically deliver within 5–10 business days. We offer expedited shipping options at checkout. Estimated delivery dates are shown on each product page.
Yes! All products come with manufacturer warranties. Lifts typically carry 1–3 year structural warranties. Compressors and equipment warranties vary by brand. We also offer extended warranty programs. Contact us for specific warranty details on any product.
We offer two financing options: Synchrony Bank (Buy Now, Pay Over Time) and SLS Financial (Interest Financing). Apply at checkout in minutes. Approval is typically instant. Subject to credit approval. See individual product pages for financing availability.
We partner with certified installation professionals nationwide. Installation quotes are available at checkout for select items. You can also find installation guides in our support center for DIY customers. Our expert team is available to walk you through the process.
Can't find what you're looking for? Our team is here to help.