Specifications
-| Model | LANAIR XT75 |
|---|---|
| Overall Length | 26 |
| Overall Width | 21 |
| Overall Height | 75 |
| Overall Weight | 210 |
| Voltage | 115V |
Warranty
-Resources
-
For more detailed information and guidance, you can download the following:
Description
-Lanair XT75: the waste oil heater that brings its own air compressor
Every waste oil burner needs compressed air to atomise the fuel, and on the larger XT cabinets that means running a permanent air line from your shop compressor to the heater and keeping that compressor healthy for as long as you want heat. The XT75 does not ask for any of that. It has an onboard air compressor, so the appliance is self-contained.
Read that alongside the rest of the specification and a pattern appears. It runs on 115 V at 8 amps — an ordinary wall circuit, not the heavier dedicated feed the bigger cabinets want. It stands on the floor rather than hanging from your roof structure, on a footprint of 21" by 26". And it arrives preassembled. Of everything in Lanair's range, this is the unit you can realistically install in a building that was never designed around it.
Vertical on purpose
The XT75 is 75" tall and occupies about the floor area of a filing cabinet. That shape is the whole idea: a small shop does not have spare wall, but it almost always has a spare corner, and a tall narrow appliance takes the corner without eating a work zone. Lanair describes the design as customer-inspired, which reads like marketing until you have tried to find room for a hanging heater in a two-bay building with a mezzanine and a compressor already in the way.
Going vertical also puts the controls and the service points at standing height. You are not on a ladder to read a draft gauge or clean a strainer, which in practice is the difference between maintenance that happens and maintenance that gets postponed.
Will It Fit?
- Floor space: 21" wide by 26" deep. Add access room at the front for servicing — the footprint is the machine, not the working envelope.
- Height: 75". Check it against a low ceiling, a mezzanine edge or a roller-door track before you commit, and remember the flue leaves the top.
- Electrical: 115 V, 8 amps. That is a standard circuit, which is the single biggest reason this unit ends up in buildings the bigger cabinets cannot go into.
- Compressed air: none required externally. The compressor is on board.
- Flue: 6" Class A pipe, exiting from the top. The chimney kit supplied covers a roof or wall exit and is sized for 14-16 eaves.
- Floor: level and solid. It is floor-mounted, so this is a much simpler question than the structural check a suspended heater demands — but the weight is on the specification table below and worth reading before you slide it into position.
Confirming clearances against your own building is the buyer's responsibility. The height is the one people miss.
The small parts that decide how it ages
Four items in this unit's feature list are the ones an owner actually interacts with.
The metering pump delivers fuel at a controlled rate rather than relying on gravity or line pressure, which is what makes a consistent flame possible on a fuel whose viscosity changes with what was drained into the tank last week.
The draft gauge is the diagnostic you get for free. Draft is what a waste oil appliance lives or dies by, and a gauge on the machine means you can see a blocked flue or a failing chimney as a number instead of discovering it as a burner that keeps shutting down.
The cleanable in-tank strainer is the acknowledgement that used oil carries debris. Cleanable, not replaceable — you rinse it and put it back rather than ordering a part every service.
And it is preassembled, which for a small shop without an in-house installer is a genuine cost item, not a convenience note.
Fuel and output
Rated at 75,000 BTU heating up to 1,700 sq. ft., at a fuel input of 0.54 GPH. It burns #1 and #2 fuel oil (diesel), used crankcase oil in conventional or synthetic form, and used automatic transmission fluid.
The output figure is the one to be honest with yourself about. 1,700 sq. ft. is a small shop, a two-bay building or a large home workshop — it is not a warehouse, and no amount of louvre adjustment will make it one. If your building is closer to 3,500 sq. ft., look at the larger XT cabinets instead, accepting that they will want a shop air line and a heavier circuit.
Keep the tank clean. Gasoline, solvent, antifreeze, brake fluid and paint waste do not belong in a waste oil heater, and contaminated fuel is the most common cause of a burner that will not run — it is also not a warranty fault.
Perfect For
- Small independent shops of one or two bays doing regular oil changes.
- Home and hobby garages serious enough to generate drain oil but without three-phase power or a big compressor.
- Buildings with no spare wall or ceiling structure, where a corner is the only place left.
- Rented units where hanging an appliance from the roof structure is not permitted.
- Farm and equipment sheds heating a working area rather than a whole building.
What's in the Box
The unit is supplied preassembled, with an onboard air compressor, metering pump, draft gauge and a cleanable in-tank strainer fitted. A chimney provision for roof and wall exit is included, comprising a 6" chimney sized for 14-16 eaves. Nothing beyond that is claimed here, because nothing beyond that is stated in the product data.
Specifications
| Model | XT75 |
|---|---|
| Heat range | Up to 75,000 BTUH |
| Heating area | Up to 1,700 sq. ft. |
| Fuel input | 0.54 GPH |
| Cabinet (L x W x H) | 26" x 21" x 75" |
| Power supply | 115 V, 8 amps |
| Air supply | Onboard compressor — no shop air line required |
| Chimney pipe | 6" Class A, top exit |
| Ductable | No |
| Mounting | Floor mounted |
Certification, honestly
The product data behind this listing does not record a third-party safety listing for the XT75, and we are not going to imply one. Lanair's copy on other units in its range does make a listing claim; this record does not repeat it, which is a question worth asking rather than a gap worth glossing over.
It matters in three places, all of them local: the permit for a used-oil burning appliance and its flue, an insurer's conditions on your building, and any corporate or landlord policy that wants documentation on file. If one of those applies to you, ask us to confirm the listing status in writing before you order. That is quick to establish beforehand and awkward to resolve once the unit is installed in a corner.
Shipping and Delivery
Freight to the lower 48 states, with the cost quoted live at checkout rather than fixed on this page. Two things to plan. Unloading is the customer's: even the smallest cabinet in this range is a crated appliance, so you need a forklift, a dock, or an arrangement to collect it from the carrier's terminal. And residential delivery is a distinct service carrying a fee, so tell us which type of address it is going to. On arrival, inspect the crate before you sign for it — write any damage on the bill of lading at that moment, photograph it, and keep the packaging. A clean signature is very hard to argue with afterwards.
Warranty
The manufacturer's warranty applies. The specific terms are not held in the data behind this listing, so rather than approximate them we will send you to the source: our warranty claims page explains how to raise a claim. One thing worth knowing before you need it — do not take the unit apart first. A burner or a chamber opened up before the claim is raised usually ends the claim, because the manufacturer wants to see the fault as it actually presented.
Product Features
- 75,000 BTU’s heat up to 1,700 sq. ft.
- Burns #1 and #2 fuel oil (diesel), used crankcase oil (conventional or synthetic), and used ATF
- Small footprint; only 21”W X 26”L floor mounted footprint
- Onboard air compressor
- Metering pump
- Draft gauge
- Cleanable in-tank strainer
- Preassembled for easy installation
- Roof and wall includes 6” chimney for 14-16 eves
Product Specifications
| Heat Range (BTUH) | Up to 75,000 |
| Fuel Input (GPH) | 0.54 |
| Fuel Type | Burns #1 and #2 fuel oil (diesel), used crankcase oil (conventional or synthetic), and used ATF |
| Heating Area (sq. ft.) | Up to 1,700 |
| Power Supply (AC) | 115 V-60Hz 8 Amps |
| Cabinet Dimensions (L x W x H) | 26" x 21" x 75" |
| Hanging Weight (lbs.) | 210 |
| Chimney Pipe | 6" Class A |
| Axial Fan (CFM) | 500 |
| Ductable Option | No |
| Chimney Location | Top |
Frequently Asked Questions
Everything you need to know about our products and services
After placing your order, you'll receive a confirmation email within minutes. Our team will process your order within 1–2 business days. For large items like vehicle lifts, a freight carrier will contact you to schedule delivery. Smaller items ship via UPS or FedEx.
We offer a 30-day return policy for most items in original, unused condition. Vehicle lifts and heavy equipment may have restocking fees. Freight items must be inspected at delivery and any damage noted on the bill of lading. Contact us within 48 hours of delivery for damage claims.
Absolutely! We offer special pricing for shops, contractors, and bulk orders. Contact our sales team at 866-774-7743 or email sales@mechanicsuperstore.com for a custom quote. Volume discounts start at 3+ units.
Tracking information is sent once your order ships. If you haven't received it within 2 business days, check your spam folder. You can also track your order by logging into your account or contacting our support team at support@mechanicsuperstore.com.
Standard orders ship within 1–3 business days. Freight items (lifts, compressors) typically deliver within 5–10 business days. We offer expedited shipping options at checkout. Estimated delivery dates are shown on each product page.
Yes! All products come with manufacturer warranties. Lifts typically carry 1–3 year structural warranties. Compressors and equipment warranties vary by brand. We also offer extended warranty programs. Contact us for specific warranty details on any product.
We offer two financing options: Synchrony Bank (Buy Now, Pay Over Time) and SLS Financial (Interest Financing). Apply at checkout in minutes. Approval is typically instant. Subject to credit approval. See individual product pages for financing availability.
We partner with certified installation professionals nationwide. Installation quotes are available at checkout for select items. You can also find installation guides in our support center for DIY customers. Our expert team is available to walk you through the process.
Can't find what you're looking for? Our team is here to help.